Search results for "DC stre"
showing 10 items of 10 documents
Space charge behavior of different insulating materials employed in AC and DC cable systems
2017
In this work, the space charge accumulation in three different XLPE based material has been carried out by using the PEA (Pulsed Electro-Acoustic) method. The specimens provided by a cables industry have been subjected to the same DC stress during polarization time at environment temperature. Afterwards, the high voltage generator has been turned off and the amount residual charge has been evaluated. The space charge profiles during polarization and depolarization have been carried out and compared. Finally, the distribution of electric field within the samples has been reported. In particular, the maximum distortion of electric field has been calculated by taking into account the distribut…
The Effect of the Harmonic Content Generated by AC/DC Modular Multilevel Converters on HVDC Cable Systems
2019
With the increasing penetration of renewable and decentralized energy sources into the power grid, an extended use of DC voltages is expected on both distribution and transmission levels. Generation of DC voltages by means of voltage source converters is associated with a wide spectrum of harmonic distortions at converter terminals, both on the ac and on the dc sides. This can lead to partial discharges in power cables, which deteriorate insulation material thus weakening its performance and reducing cable life-time. In the previously published paper, the effect of harmonic distortion on appearance of partial discharges in cable insulation was evaluated. Here, the study related to the PD be…
Partial discharges behavior under different rectified waveforms
2017
In this work, a previous software used to simulate partial discharges (PDs) under Alternating Current (AC) stress has been modified in order to evaluate the PDs behavior under a voltage stress close to the Direct Current (DC) waveform. By using a full-wave and a half-wave rectifier, the specimen with an air void defects has been subjected to a gradual constant stress. Finally, a capacitive filter has been inserted in order to produce a steadier voltage supply. Simulation results show that under an almost DC waveform, the PDs activity become less compared to AC stress.
Different Space Charge Behavior of Materials Used in AC and DC Systems
2017
The aim of the present work is to evaluate the behavior, from the space charge accumulation phenomenon point of view, of three different XLPE specimens used as insulation materials in high voltage systems. Considering that under DC stress the charge accumulation is more relevant as compared to the AC case, in the specimens for DC applications additives are typically added. In this work, three different specimens are analyzed. One is a free additive sample used conventionally under AC stress and two others include different additives that are used under DC stress. In order to measure the space charge accumulation, the Pulsed Electro Acoustic (PEA) method has been employed. For each sample, t…
Partial Discharge Measurements under DC Voltages Containing Harmonics Produced by Power Electronic Devices
2018
Partial Discharge (PD) monitoring is one of the main diagnostic instrument to evaluate the reliability of modern electrical transmission and distribution systems. The widespread use of High voltage dc (HVDC) connections increase the demand of voltage source converters (VSCs) which, as a consequence, has brought about new challenges in the field of partial discharge measurements. In fact, the output voltage waveforms generated by AC/DC modular multilevel converters (MMCs) are affected by a significant harmonic content which influences the Partial Discharges (PDs) activity. For this reason, previous research mainly investigated the PD phenomenon on the AC side of the converter. The aim of the…
A new technique for partial discharges measurement under DC periodic stress
2017
The aim of the present work is to recognize the type of defect in insulating materials employed in DC electrical systems. This analysis, under AC stress, is carried out by using the Phase Resolved method (PRPD). While, under constant voltage stress this method cannot be performed and measurements show complexities. In order to overcome these problems, a new technique is proposed, based on the application of a periodic continuous waveform. Simulation results, carried out by using a model based on a time-variable conductance of an air void defect, showed the PRPD pattern that can be obtain. Furthermore, compared to the constant DC stress, the measurement duration became lower and the discharg…
The Partial Discharge Behavior of Different Materials under DC Periodic Stress
2019
The aim of the present work is to evaluate the PDs behavior by stressing a specimen with a new type of waveform named DCP. This waveform was proposed by the authors in a previous work with the aim to overcome the main issues of PDs under DC stress. In the previous work PDs test on Kapton specimen was performed. In this paper, we propose a new DCP test on a different insulating material, such as the XLPE. The obtained patterns and the acquired data have been evaluated in order to validate the DCP approach as a new method for PDs measure under constant stress. The behavior of the XLPE material has been reported and compared with the former measures obtained for Kapton material.
Space Charges and Partial Discharges Simultaneous Measurements under DC Stress
2016
In the field of HVDC, the main causes of insulation aging are due to the space charge and PD phenomena. In particular, the purpose of the present work is to verify a possibility to measure simultaneously the space charge and the PDs under DC stress in order to evaluate the correlation between both phenomena. The space charge was measured by using a modified PEA cell and PDs were measured by using a novel wireless sensor system. The space charge profile and the PD pulses carried out simultaneously have been reported and discussed.
Partial discharge behavior under single phase half and full-bridge rectifier
2017
The aim of the present work is to simulate partial discharges (PDs) phenomena under voltage stress close to the Direct Current (DC) waveform. The employed waveforms have been realized by using a full-wave and a half-wave rectifiers. After that, in order to generate a steadier voltage supply, a capacitive filter has been inserted in the output of the half-wave rectifier. Simulations have been carried out by modifying a previous software used in the case of Alternating Current (AC). Finally, experimental tests have been carried out in order to validate simulation results.
Space Charge Measurement under DC and DC Periodic Waveform
2018
In High Voltage systems, Partial Discharges (PDs) monitoring are one of the main diagnostic instrument to evaluate the reliability of the apparatus. Under Alternating Current (AC) stress, PDs detection and recognition techniques are well consolidated. On the contrary, the monitoring of PDs under Direct Current (DC) stress is difficult due to complexities related to the nature of the phenomenon, which cause the beginning of PDs events in proximity of the dielectric breakdown. This problem has been partially overcome by using a continuous Periodic waveform (DCP) with positive average value, as described in a recent published work. Under DC stress, another degradation factor is the Space Charg…